Pre Insulated Tube Performance Data

TUBE

Stainless steel Copper
ASTM A269 ASTM B68
ASTM A213 ASTM B75
ASTM A249 ASTM B88
Common Tube Materials and Sizes

CM TECH’s standard tubing materials are 304/304L
semi-seamless and 316/316L seamless stainless steel,
type 1220 copper tube. In case of using other materials,
available upon requested.





BTV Heating Cable for Freeze Protection (under 60℃ Max. Process Temperature)
Product Overview
TEMPERATURE RATING

Maximum maintain or continuous exposure temperature(power on)

65℃

Maximum intermittent exposure temperature, 1000 hours (power on or off)

85℃

Minimum installation temperature

-40℃

Read more




Insulation Specification

- E-GLASS FIBER Insulation
Typical Properties Value
Basis Weight 2340g/㎡
Thickness 13mm
Ash (600℃, 1hr) 97%
Density 180kg/㎥
Thermal Conductivity (20℃) 0.034 w/m°K
Chloride 6ppm or Less
RoHS (Pb,Cd,Hg,Cr6+) NONE
Component (KS L 2101)  
-SiO2 52~62%
-Al2O3 11~16%
- E-GLASS FIBER Insulation

Typical Properties

Value
Thickness 5mm, 10mm
Density 180
Thermal Conductivity 0.014 w/m ˚K
Use Temperature -200~650℃
Hydrophobic Yes
Read more




PVC Jacket

Typical Properties CM Standard Value ASTM D 1047-11
Tensile Yield strength, min, Mpa 2800 1500
Elongation at rupture, min, % 300 100
after Air Oven Aging Test at 136±1℃ for 7days
Tensile Yield strength
min, Mpa Elongation at rupture, min, %

123
53
100±1℃ for 5days
85
60
Heat shock, 136±1 ℃ No crack No crack but 121±1 ℃
Cold bend, -40±1 ℃ No crack No crack but -35±1 ℃
LOI (Limited Qxygen Index) 30