- Impulse lines : to flow transmitters, pressure transmitters, level transmitters, and pressure switches
- Sample lines : On-line analyzers
- Process lines : for steam supply, condensate collection, water purge, chemical feed, and air(vapor) line
Process tube maintain temperature (min.~max.) for ambient range of -30~38℃) at 120/240V |
|||
Tube O.D. | 1/4 | 3/8 | 1/2 |
SINGLE | Min.~Max | Min.~Max | Min.~Max |
SL 5Watt | 19~52℃ | 16~51℃ | 14~50℃ |
SL 8Watt | 32~58℃ | 29~57℃ | 27~56℃ |
PL 5Watt | 31~92℃ | 26~88℃ | 21~84℃ |
PL 10Watt | 63~110℃ | 56~105℃ | 51~101℃ |
PL 15Watt | 84~126℃ | 78~120℃ | 71~116℃ |
PL 20Watt | 111~151℃ | 103~145℃ | 96~139℃ |
DUAL | Min.~Max | Min.~Max | Min.~Max |
SL 5Watt | 18~52℃ | 14~50℃ | 12~49℃ |
SL 8Watt | 32~58℃ | 28~56℃ | 24~55℃ |
PL 5Watt | 29~91℃ | 22~85℃ | 16~80℃ |
PL 10Watt | 61~109℃ | 52~102℃ | 44~96℃ |
PL 15Watt | 83~124℃ | 73~116℃ | 64~110℃ |
PL 20Watt | 109~149℃ | 97~140℃ | 87~132℃ |
* SL : Self-Regulating, PL : Power-Limiting
Overview of SL and PL heating cable characteristics |
||||
Heating cable |
Service voltage | Maximum continuous exposure temperature | Maximum intermittent exposure temperature | T-rating/ maximum sheath temperature |
SL all types | 110/120V | 65℃ | 85℃ | T6 85℃ |
SL all types | 208/277V | 65℃ | 85℃ | T6 85℃ |
PL 5,10watt | 110/120V | 121℃ | 215℃ | T3 200℃ |
PL 15, 20Watt | 110/120V | 121℃ | 215℃ | T2D 215℃ |
PL 5, 10,15Watt | 208/277V | 121℃ | 215℃ | T3 200℃ |
PL 20Watt | 208/277V | 121℃ | 215℃ | T2C 230℃ |
Heating cable power on(=maximum maintain temperature) For 1,000 hours intermittent (power on or off) Higher maximum sheath temperatures have been approved by other agencies
CM TECH’s standard tubing materials are 304/304L semi-seamless and 316/316L seamless stainless steel, type 1220 copper tube. In case of using other materials, available upon requested. Regarding Selection of Process tube and Steam tube material, CM TECH recommended that using same tube material for bundle. This prevent from twisting bundle tube by heat expansion. CM TECH recommended using same tube materials for bundle.
Stainless steel |
---|
ASTM A269 |
ASTM A213 |
ASTM A249 |
Copper |
---|
ASTM B68 |
ASTM B75 |
ASTM B88 |
Tubing bundle options |
|||
Material |
Size | ||
1/4 | 3/8 | 1/2 | |
304/304L | |||
0.035 | O | O | O |
0.049 | O | O | O |
316/316L | |||
0.035 | O | O | O |
0.049 | O | O | O |
Copper | |||
0.030 | O | ||
0.032 | O | ||
0.049 | O | ||
PFA Teflon | |||
0.030 | O | O | |
0.060 | O |
Size & Bend Radius. |
|||
Tube O.D |
Nominal Bundle O.D(in) | Minimum bend radius(in) | Run length(m) |
1/4 | 1.5 | 7.0 | 250~300 |
3/8 | 1.6 | 7.0 | 250~300 |
1/2 | 1.8 | 8.0 | 250~300 |
3/4 | 2.0 | 10.0 | 250~300 |
WORKING PRESSURE @ 200℃ (Unit:PSI) | ||||||
TUBE WALL THICKNESS |
||||||
Tube O.D |
304 welded stainless steel | 316 seamless stainless steel | #1220 copper | |||
Th’k | 0.035 | 0.049 | 0.035 | 0.049 | 0.035 | 0.049 |
1/4 | 4222 | 6164 | 4967 | 7252 | ||
3/8 | 2740 | 3942 | 3224 | 4637 | 556 | 861 |
1/2 | 2154 | 3080 | 2543 | 3624 | 410 | 600 |
3/4 | 1416 | 2010 | 1666 | 2565 | 390 |
CM-ESS-0 : Jacket Patch Kit
CM-ESH-01 : Entry Seal Kit
CM ESS-02/03/04 : Heat Shrinkable Boots
JBS-100-A : Power connection for one heating cable in non-hazardous and hazardous locations.
S-150 : Splice kit for heating cables in non-hazardous and hazardous locations.
E-100-A : End seal for heating cable in non-hazardous and hazardous locations.
*For more information, See the Accessories section.